JavaScript isn't enabled in your browser, so this file can't be opened. Enable and reload.
TSM 120 BCA IIPP TSM QUIZ
TSM-120 Demolition - Silica Safety [PP 09/26/2021 - 10/09/2021]
PLEASE USE YOUR CITY OF LOS ANGELES EMAIL ACCOUNT......DO NOT USE ANY OTHER EMAIL HERE
* Indicates required question
Email
*
Your email
City of Los Angeles ID Number
*
Your answer
CORRECT FORMAT FOR NAME
First_Name
*
Your answer
Last_Name
*
Your answer
Class Code
*
Choose
ASST INSPECTOR I
ASST INSPECTOR II
ASST INSPECTOR III
ASST INSPECTOR IV
CONSTRUCTION INSPECTOR
OPERATG ENGRS IU-GRP I
SR CONSTRUCTION INSPECTOR
SR ELECTRICAL INSPECTOR
PR CONSTRUCTION INSPECTOR
CH CONSTRUCTION INSPECTOR
CIVIL ENGINEER
OTHER
If Class Code is "OTHER" please specify
Your answer
District
*
Choose
District 1
District 2
District 3 & 5
District 4
District 6
District 7 & 9 & 10
District 8
A1
A2
A3
A4
W1
W2
W3
POLA
LAWA
PA
MTL CTRL
TRAINING
EXEC
OCC
OWS
ADMIN
Supervisor
*
Choose
Angela Martinez
Bill Benson
Emmanuel Achonu
Jim Cassley
Johnny Brewer
Ken Hendricks
Tom Dam
Victor Karayan
Roosevelt Bagby
Brett McReynolds
Seffy Wiles
George Espindola
John Reamer, Jr.
Angelica Samayoa
Lynda McGlinchey
Kimberly Fitzpatrick
Vacant
1.
Which of the following would not be required when completing a demolition survey?
*
1 point
Hazardous Materials
Physical conditions of the facility
Adjacent buildings
Pedestrians
Vehicular traffic
Haul routes for disposal of waste materials
Cal-OSHA regulations
None; All are important to consider
2.
The risk assessment needs to be prepared prior to the demolition and reviewed as necessary to make sure it is working as planned?
*
1 point
True
False
3.
A walkway shall be provided for pedestrian travel in front of every construction and demolition site. What is the minimum width of this walkway?
*
1 point
36"
42"
48"
54"
60"
4. What is the clear height of a covered walkway?
*
1 point
72"
84"
96"
108"
5. Covered walkways must be a minimum width of how many feet from the face of a building entrance?
*
1 point
6 ft
7 ft
8 ft
Only as wide as the sidewalk; the uprights can't be in the traffic lanes.
6. Where can the inspector find the name of the Demolition Supervisor?
*
1 point
Demolition Contractor's required submittals
In the posted survey of the structure to determine the condition
Form 141 Competent person form
Site specific IIPP Demolition Work plan
All except #3
7. Per Cal-OSHA §1735. Demolishing Buildings all displace material can be stored on a floor to facilitate efficient material handling and hauling?
*
1 point
False
True
8. BCA inspectors are required to enforce all sections of §1735. Demolishing Buildings.
*
1 point
False
True
9. When operations are not in progress, the discharge end of the chute shall be securely closed off, or the area barricaded or fenced as provided in Section 1736(a)
*
1 point
True
False
10. Cal-OSHA § 1532.3 only applies when exposure to Respirable Crystalline Silica exceeds 25 micrograms per cubic meter of air (25 μg/m3) as an 8-hour time-weighted average (TWA)
*
1 point
True
False
11. § 1532.3. Occupational Exposures to Respirable Crystalline Silica Table 1 is the generally accepted method of protecting construction workers form the harmful effects of RCS?
*
1 point
False
True
12. For most demolition activities what is the preferred method of controlling materials containing Crystalline Silica?
*
1 point
Hepa Filters
Respirators
Engineering controls
Water delivery systems
Restricted access zones
A copy of your responses will be emailed to the address you provided.
Submit
Page 1 of 1
Clear form
Never submit passwords through Google Forms.
reCAPTCHA
Privacy
Terms
This form was created inside of City of Los Angeles.
Report Abuse
Forms