TO SHUT DOWN THE STEAM GENERATOR
For short stops it is necessary only
to close the stop and check valve-15;
the fire will cycle off and on, and
maintain operating pressure in the
steam generator. For terminal stops,
proceed as follows:
1 . Press the trainline shutoff button
on the remote control panel, and
close the stop and check valve-15.
Set the water by-pass regulator-
111 at maximum output and build
the generator pressure up to 200
lbs.
2. Turn the control switch-102 OFF
and open the coil Blowdown
valve-2. When the generator pres
sure drops to 75 lbs. close the coil
Blowdown valve and open the
separator Blowdown valve-12 . After
the steam separator is completely
drained, close this valve.
3. Refill the coils, then turn the control
switch-102 OFF. Close the
atomizing air valve-1, and open
the main switch