JavaScript isn't enabled in your browser, so this file can't be opened. Enable and reload.
DCARI Virtual Fire Investigation Training-Session #10 Corrugated Stainless Steel Tubing-ATF Electrical Engineer Jeremy Neagle
This recorded class is meant to be used as a guide for individuals who conduct origin and cause investigations. The link to the class is below:
Email:
dcari.danecounty@gmail.com
with any questions.
Sign in to Google
to save your progress.
Learn more
* Indicates required question
Email
*
Your email
Name (First Last)
As you want it to appear on your certificate of attendance.
Your answer
Your Department/Agency name ?
Your answer
Phone number?
Sometimes email addresses are entered incorrectly. We will only use this to contact you if there is an issue with the certificate being bounced back. WE WILL NOT SHARE THIS WITH ANYONE OUTSIDE OF THE DCARI BOARD.
Your answer
What state are you located in ?
Your answer
What country are you located in ?
United States
Other:
Clear selection
Do you investigate fires for:
Public
Private
Other:
Clear selection
1.
The polymeric jacket of yellow CSST serves an important role in safety of the CSST installation:
*
7 points
True
False
2.
Factory training for the design and installation of CSST systems may come in the form of:
*
7 points
A. In person training
B. On-line training
C. Reading manufacturer’s literature
D. All of the above
3.
Requirements for the installation of CSST systems can be found in:
*
7 points
A. NFPA 70E
B. NFPA 1901
C. NFPA 54
D. 29 CFR 1910.156
4.
According to the current edition of the National Fuel Gas Code, the minimum size bonding conductor for CSST systems is:
*
7 points
A. 14 AWG
B. 6 AWG
C. 2/0 AWG
D. 500 MCM
5.
CSST installed in which of the following locations requires additional protection:
*
7 points
A. Where routed above suspended ceilings
B. Where routed through concealed spaces
C. Where routed through framing members
D. Where connected to a pressure regulator
6.
CSST system components are universal and can be mixed-and-matched among different manufacturers:
*
7 points
True
False
7.
A leak test which provides a measurement of volumetric flow rate is:
*
7 points
A. A soap bubble test
B. A clock test
C. A gas detector survey
D. A pressure drop test
8.
Connecting objects together to establish electrical continuity and conductivity is known as:
*
7 points
A. Bonding
B. Bridging
C. Earthing
D. Jumping
9.
According to the current edition of the National Fuel Gas Code, the maximum length of bonding conductors for CSST systems is:
*
7 points
A. 100’
B. 75’
C. 50’
D. 25’
10.
Black jacketed CSST products are immune to the lightning damage concerns of yellow jacketed CSST products:
*
7 points
True
False
11.
Courts have awarded settlements in CSST lawsuits to include:
*
7 points
A. Reimbursement for gas usage costs
B. Retrofitting of systems from LP gas to natural gas
C. Reimbursement for direct bonding and grounding of CSST systems
D. Replacement of CSST systems with steel gas piping systems
12.
CSST may be used with natural gas only:
*
7 points
True
False
13.
Lightning damage to CSST systems may result in:
*
7 points
A. Welding of brass fitting assemblies
B. Delamination of the protective jacketing
C. Perforation of the tubing and ignition of escaping gas
D. Excessive pressures in the gas system
14.
The thickness of metal used to fabricate CSST is about equivalent to that used in steel pipe or copper tube:
*
7 points
True
False
15.
Leak testing should be conducted at system pressure, but generally no more than:
*
7 points
A. 15 psig
B. 5 psig
C. 7 in. w.c.
D. 75 psig